Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Schmitt, Claus P. [VerfasserIn]   i
 Nau, Barbara Silvia [VerfasserIn]   i
 Gemulla, Gita [VerfasserIn]   i
 Sander, Anja [VerfasserIn]   i
 Schaefer, Franz [VerfasserIn]   i
Titel:Effect of the dialysis fluid buffer on peritoneal membrane function in children
Verf.angabe:Claus Peter Schmitt, Barbara Nau, Gita Gemulla, Klaus E. Bonzel, Tuula Hölttä, Sara Testa, Michel Fischbach, Ulrike John, Markus J. Kemper, Anja Sander, Klaus Arbeiter, and Franz Schaefer
Jahr:2013
Umfang:8 S.
Fussnoten:Published online 2012 Nov 2 ; Gesehen am 07.06.2018
Titel Quelle:Enthalten in: American Society of NephrologyClinical journal of the American Society of Nephrology
Ort Quelle:Washington, DC : American Society of Nephrology, 2006
Jahr Quelle:2013
Band/Heft Quelle:8(2013), 1, Seite 108-115
ISSN Quelle:1555-905X
Abstract:Background and objectives: Double-chamber peritoneal dialysis fluids exert less toxicity by their neutral pH and reduced glucose degradation product content. The role of the buffer compound (lactate and bicarbonate) has not been defined in humans. Design, setting, participants, & measurements: A multicenter randomized controlled trial in 37 children on automated peritoneal dialysis was performed. After a 2-month run-in period with conventional peritoneal dialysis fluids, patients were randomized to neutral-pH, low-glucose degradation product peritoneal dialysis fluids with 35 mM lactate or 34 mM bicarbonate content. Clinical and biochemical monitoring was performed monthly, and peritoneal equilibration tests and 24-hour clearance studies were performed at 0, 3, 6, and 10 months. Results: No statistically significant difference in capillary blood pH, serum bicarbonate, or oral buffer supplementation emerged during the study. At baseline, peritoneal solute equilibration and clearance rates were similar. During the study, 4-hour dialysis to plasma ratio of creatinine tended to increase, and 24-hour dialytic creatinine and phosphate clearance increased with lactate peritoneal dialysis fluid but not with bicarbonate peritoneal dialysis fluid. Daily net ultrafiltration, which was similar at baseline (lactate fluid=5.4±2.6 ml/g glucose exposure, bicarbonate fluid=4.9±1.9 ml/g glucose exposure), decreased to 4.6±1.0 ml/g glucose exposure in the lactate peritoneal dialysis fluid group, whereas it increased to 5.1±1.7 ml/g glucose exposure in the bicarbonate content peritoneal dialysis fluid group (P=0.006 for interaction). Conclusions: When using biocompatible peritoneal dialysis fluids, equally good acidosis control is achieved with lactate and bicarbonate buffers. Improved long-term preservation of peritoneal membrane function may, however, be achieved with bicarbonate-based peritoneal dialysis fluids.
DOI:doi:10.2215/CJN.00690112
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

kostenfrei: Volltext: http://dx.doi.org/10.2215/CJN.00690112
 kostenfrei: Volltext: https://journals.lww.com/cjasn/fulltext/2013/01000/effect_of_the_dialysis_fluid_buffer_on_peritoneal.16.aspx
 DOI: https://doi.org/10.2215/CJN.00690112
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1576131300
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68258722   QR-Code
zum Seitenanfang