Titel:Improved compressed sensing reconstruction for 19F magnetic resonance imaging
Verf.angabe:Thomas Kampf, Volker J.F. Sturm, Thomas C. Basse-Lüsebrink, André Fischer, Lukas R. Buschle, Felix T. Kurz, Heinz-Peter Schlemmer, Christian H. Ziener, Sabine Heiland, Martin Bendszus, Mirko Pham, Guido Stoll, Peter M. Jakob
E-Jahr:2019
Jahr:2 January 2019
Umfang:15 S.
Fussnoten:Im Text ist die Zahl 19 hochgestellt ; Gesehen am 20.05.2019
Titel Quelle:Enthalten in: Magnetic resonance materials in physics, biology and medicine
Ort Quelle:Heidelberg : Springer, 1993
Jahr Quelle:2019
Band/Heft Quelle:32(2019), 1, Seite 63-77
ISSN Quelle:1352-8661
Abstract:ObjectiveIn magnetic resonance imaging (MRI), compressed sensing (CS) enables the reconstruction of undersampled sparse data sets. Thus, partial acquisition of the underlying k-space data is sufficient, which significantly reduces measurement time. While 19F MRI data sets are spatially sparse, they often suffer from low SNR. This can lead to artifacts in CS reconstructions that reduce the image quality. We present a method to improve the image quality of undersampled, reconstructed CS data sets.Materials and methodsTwo resampling strategies in combination with CS reconstructions are presented. Numerical simulations are performed for low-SNR spatially sparse data obtained from 19F chemical-shift imaging measurements. Different parameter settings for undersampling factors and SNR values are tested and the error is quantified in terms of the root-mean-square error.ResultsAn improvement in overall image quality compared to conventional CS reconstructions was observed for both strategies. Specifically spike artifacts in the background were suppressed, while the changes in signal pixels remained small. DiscussionThe proposed methods improve the quality of CS reconstructions. Furthermore, because resampling is applied during post-processing, no additional measurement time is required. This allows easy incorporation into existing protocols and application to already measured data.
DOI:doi:10.1007/s10334-018-0729-1
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1007/s10334-018-0729-1
 DOI: https://doi.org/10.1007/s10334-018-0729-1
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:19F
 Artifact
 Compressed sensing
 CSI
 MRI
 MRSI
 Sparse
K10plus-PPN:1665925108
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68391172   QR-Code
zum Seitenanfang