Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Meyer, Mathias [VerfasserIn]   i
 Schönberg, Stefan [VerfasserIn]   i
Titel:Comparison of iodine quantification and conventional attenuation measurements for differentiating small, truly enhancing renal masses from high-attenuation nonenhancing renal lesions with dual-energy CT
Verf.angabe:Mathias Meyer, Rendon C. Nelson, Federica Vernuccio, Fernando Gonzalez, Christoph Schabel, Achille Mileto, Bhavik N. Patel, Stefan O. Schoenberg, Daniele Marin
Jahr:2019
Umfang:12 S.
Fussnoten:Gesehen am 31.07.2019
Titel Quelle:Enthalten in: American journal of roentgenology
Ort Quelle:Leesburg, Va. : American Roentgen Ray Society, 1965
Jahr Quelle:2019
Band/Heft Quelle:213(2019,1) Seite W26-W37, 12 Seiten
ISSN Quelle:1546-3141
Abstract:OBJECTIVE: The purpose of this study is to determine whether iodine quantification techniques from contrast-enhanced dual-energy CT (DECT) data allow equal differentiation of small enhancing renal masses from high-attenuation (> 20 HU of unenhanced attenuation) nonenhancing lesions, compared with conventional attenuation measurements. - MATERIALS AND METHODS: A total of 220 nonconsecutive patients (mean [± SD] age, 66 ± 13 years; 130 men and 90 women) with 265 high-attenuation renal lesions (mean attenuation, 54 ± 33 HU; 91 enhancing lesions) were included. Each patient underwent single-energy unenhanced CT followed by DECT during the nephrographic phase using one of four different high-end DECT platforms (first- and second-generation rapid-kilovoltage-switching DECT platforms and second- and third-generation dual-source DECT platforms). Iodine quantification measurements and conventional attenuation change measurements were calculated for each lesion. Diagnostic accuracy was determined by pathologic analysis, confirmation with another imaging modality, or greater than 24 months of imaging follow-up as the reference standard. - RESULTS: The diagnostic accuracy for differentiating enhancing from nonenhancing renal lesions was significantly higher for conventional attenuation change measurements, compared with iodine quantification measurements (AUC values, 0.973 vs 0.875; p < 0.0001). The diagnostic performance of iodine quantification measurements improved only marginally with the utilization of DECT platform-specific optimized iodine quantification thresholds, yielding AUC values of 0.907 and 0.893 for the rapid-kilovoltage-switching DECT and dual-source DECT platforms, respectively. Unenhanced lesion attenuation (p = 0.0010) and intraparenchymal location (p = 0.0249) significantly influenced the diagnostic accuracy of the iodine quantification techniques. - CONCLUSION: Iodine quantification from DECT data yields inferior diagnostic accuracy when compared with conventional attenuation change measurements for differentiating small, truly enhancing renal masses and high-attenuation renal lesions.
DOI:doi:10.2214/AJR.18.20547
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.2214/AJR.18.20547
 DOI: https://doi.org/10.2214/AJR.18.20547
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:dual energy
 enhancement
 iodine quantification
 renal lesion
K10plus-PPN:1670338274
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68414478   QR-Code
zum Seitenanfang