Titel:Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning
Verf.angabe:Sebastian Meyer, Florian Kamp, Thomas Tessonnier, Andrea Mairani, Claus Belka, David J. Carlson, Chiara Gianoli and Katia Parodi
E-Jahr:2019
Jahr:12 June 2019
Umfang:10 S.
Fussnoten:Gesehen am 19.09.2019
Titel Quelle:Enthalten in: Physics in medicine and biology
Ort Quelle:Bristol : IOP Publ., 1956
Jahr Quelle:2019
Band/Heft Quelle:64(2019,12) Artikel-Nummer 125008, 10 Seiten
ISSN Quelle:1361-6560
Abstract:Ion computed tomography (iCT) represents a potential replacement for x-ray CT (xCT) in ion therapy treatment planning to reduce range uncertainties, inherent in the semi-empirical conversion of xCT information into relative stopping power (RSP). In this work, we aim to quantify the increase in dosimetric accuracy associated with using proton-, helium- and carbon-CT compared to conventional xCT for clinical scenarios in proton therapy. Three cases imaged with active beam-delivery using an ideal single-particle-tracking detector were investigated using FLUKA Monte-Carlo (MC) simulations. The RSP accuracy of the iCTs was evaluated against the ground truth at similar physical dose. Next, the resulting dosimetric accuracy was investigated by using the RSP images as a patient model in proton therapy treatment planning, in comparison to common uncertainties associated with xCT. Finally, changes in relative biological effectiveness (RBE) with iCT particle type/spectrum were investigated by incorporating the repair-misrepair-fixation (RMF) model into FLUKA, to enable first insights on the associated biological imaging dose. Helium-CT provided the lowest overall RSP error, whereas carbon-CT offered the highest accuracy for bone and proton-CT for soft tissue. For a single field, the average relative proton beam-range variation was -1.00%, +0.09%, -0.08% and -0.35% for xCT, proton-, helium- and carbon-CT, respectively. Using a 0.5%/0.5mm gamma-evaluation, all iCTs offered comparable accuracy with a better than 99% passing rate, compared to 83% for xCT. The RMF model predictions for RBE for cell death relative to a diagnostic xCT spectrum were 0.82-0.85, 0.85-0.89 and 0.97-1.03 for proton-, helium-, and carbon-CT, respectively. The corresponding RBE for DNA double-strand break induction was generally below one. iCT offers great dinical potential for proton therapy treatment planning by providing superior dose calculation accuracy as well as lower physical and potentially biological dose exposure compared to xCT. For the investigated dose level and ideal detector, proton-CT and helium-CT yielded the best performance.
DOI:doi:10.1088/1361-6560/ab0fdf
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1088/1361-6560/ab0fdf
 Volltext: https://doi.org/10.1088%2F1361-6560%2Fab0fdf
 DOI: https://doi.org/10.1088/1361-6560/ab0fdf
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:carbon computed tomography
 ct
 dose calculation
 energy
 helium computed tomography
 heterogeneous medium
 integration
 ion computed tomography
 monte-carlo-simulation
 path
 performance
 proton computed tomography
 proton therapy
 range uncertainties
 relative biological effectiveness
 repair misrepair-fixation (RMF) model
 x-ray