Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Weymann, Alexander [VerfasserIn]   i
 Schmack, Bastian [VerfasserIn]   i
 Korkmaz-İçöz, Sevil [VerfasserIn]   i
 Chaimow, Nicole [VerfasserIn]   i
 Veres, Gábor [VerfasserIn]   i
 Karck, Matthias [VerfasserIn]   i
 Szabó, Gábor [VerfasserIn]   i
Titel:Total aortic arch replacement
Titelzusatz:superior ventriculo-arterial coupling with decellularized allografts compared with conventional prostheses
Verf.angabe:Alexander Weymann, Tamás Radovits, Bastian Schmack, Sevil Korkmaz, Shiliang Li, Nicole Chaimow, Ines Pätzold, Peter Moritz Becher, István Hartyánszky, Pál Soós, Gergő Merkely, Balázs Tamás Németh, Roland Istók, Gábor Veres, Béla Merkely, Konstantin Terytze, Matthias Karck, Gábor Szabó
E-Jahr:2014
Jahr:July 31, 2014
Umfang:10 S.
Fussnoten:Gesehen am 29.07.2020
Titel Quelle:Enthalten in: PLOS ONE
Ort Quelle:San Francisco, California, US : PLOS, 2006
Jahr Quelle:2014
Band/Heft Quelle:9(2014,7) Artikel-Nummer e103588, 10 Seiten
ISSN Quelle:1932-6203
Abstract:Background: To date, no experimental or clinical study provides detailed analysis of vascular impedance changes after total aortic arch replacement. This study investigated ventriculoarterial coupling and vascular impedance after replacement of the aortic arch with conventional prostheses vs. decellularized allografts. Methods: After preparing decellularized aortic arch allografts, their mechanical, histological and biochemical properties were evaluated and compared to native aortic arches and conventional prostheses in vitro. In open-chest dogs, total aortic arch replacement was performed with conventional prostheses and compared to decellularized allografts (n = 5/group). Aortic flow and pressure were recorded continuously, left ventricular pressure-volume relations were measured by using a pressure-conductance catheter. From the hemodynamic variables end-systolic elastance (Ees), arterial elastance (Ea) and ventriculoarterial coupling were calculated. Characteristic impedance (Z) was assessed by Fourier analysis. Results: While Ees did not differ between the groups and over time (4.1±1.19 vs. 4.58±1.39 mmHg/mL and 3.21±0.97 vs. 3.96±1.16 mmHg/mL), Ea showed a higher increase in the prosthesis group (4.01±0.67 vs. 6.18±0.20 mmHg/mL, P<0.05) in comparison to decellularized allografts (5.03±0.35 vs. 5.99±1.09 mmHg/mL). This led to impaired ventriculoarterial coupling in the prosthesis group, while it remained unchanged in the allograft group (62.5±50.9 vs. 3.9±23.4%). Z showed a strong increasing tendency in the prosthesis group and it was markedly higher after replacement when compared to decellularized allografts (44.6±8.3dyn·sec·cm−5 vs. 32.4±2.0dyn·sec·cm−5, P<0.05). Conclusions: Total aortic arch replacement leads to contractility-afterload mismatch by means of increased impedance and invert ventriculoarterial coupling ratio after implantation of conventional prostheses. Implantation of decellularized allografts preserves vascular impedance thereby improving ventriculoarterial mechanoenergetics after aortic arch replacement.
DOI:doi:10.1371/journal.pone.0103588
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext ; Verlag: https://doi.org/10.1371/journal.pone.0103588
 Volltext: https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0103588
 DOI: https://doi.org/10.1371/journal.pone.0103588
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Aorta
 Blood pressure
 Collagens
 Elastin
 Hemodynamics
 Medical implants
 Prosthetics
 Transmission electron microscopy
K10plus-PPN:1725854783
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68621777   QR-Code
zum Seitenanfang