Titel: | Towards FAIR |
Titelzusatz: | first measurements of metallic magnetic calorimeters for high-resolution x-ray spectroscopy at GSI |
Verf.angabe: | D. Hengstler, M. Keller, C. Schötz, J. Geist, M. Krantz, S. Kempf, L. Gastaldo, A. Fleischmann, T. Gassner, G. Weber, R. Märtin, Th Stöhlker, C. Enss |
E-Jahr: | 2015 |
Jahr: | 26 November 2015 |
Fussnoten: | Gesehen am 24.08.2020 |
Titel Quelle: | Enthalten in: Physica scripta |
Ort Quelle: | Bristol : IoP Publ., 1970 |
Jahr Quelle: | 2015 |
Band/Heft Quelle: | T166(2015) Artikel-Nummer 014054, ? Seiten |
ISSN Quelle: | 1402-4896 |
Abstract: | Metallic magnetic calorimeters are energy dispersive particle detectors that are operated at temperatures below . Applied to x-ray spectroscopy they combine the high energy resolution of crystal spectrometers with the large energy bandwidth of semiconductor detectors. After the absorption of a photon its energy is converted into heat. A paramagnetic alloy converts the temperature change into a change of magnetization that is read out by a sensitive superconducting quantum interference device magnetometer. With such a metallic magnetic calorimeter we performed two successful measurements at the internal gas target of the experimental storage ring at GSI. In the first beamtime lithium-like Au-ions were targeted on a N2 and a Xe gas target, respectively. In the second beamtime we observed a projectile beam of bare Xe ions interacting with a Xe gas target. In both experiments we achieved an energy resolution below from to . We were able to detect K-lines of Xe ions of different charge states, including the Lyman series up to Ly-η and could resolve the Ly-β-doublet in H-like Xe. |
DOI: | doi:10.1088/0031-8949/2015/T166/014054 |
URL: | Bibliographic entry. University members only receive access to full-texts for open access or licensed publications.