Navigation überspringen
Universitätsbibliothek Heidelberg
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Togawa, Riku [VerfasserIn]   i
 Binder, Leah-Larissa [VerfasserIn]   i
 Feißt, Manuel [VerfasserIn]   i
 Barr, Richard G. [VerfasserIn]   i
 Fastner, Sarah [VerfasserIn]   i
 Gomez, Christina [VerfasserIn]   i
 Hennigs, André [VerfasserIn]   i
 Nees, Juliane [VerfasserIn]   i
 Pfob, André [VerfasserIn]   i
 Schäfgen, Benedikt [VerfasserIn]   i
 Stieber, Anne [VerfasserIn]   i
 Riedel, Fabian [VerfasserIn]   i
 Heil, Jörg [VerfasserIn]   i
 Golatta, Michael [VerfasserIn]   i
Titel:Shear wave elastography as a supplemental tool in the assessment of unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination
Verf.angabe:Riku Togawa, MD, Leah-Larissa Binder, Manuel Feisst, Richard G. Barr, MD, Sarah Fastner, MD, Christina Gomez, MD, André Hennigs, MD, Juliane Nees, MD, André Pfob, MD, Benedikt Schäfgen, MD, Anne Stieber, MD, Fabian Riedel, MD, Jörg Heil, MD, and Michael Golatta, MD
E-Jahr:2022
Jahr:November 2022
Umfang:6 S.
Fussnoten:Online veröffentlicht: 19. September 2022 ; Gesehen am 20.02.2023
Titel Quelle:Enthalten in: BJR
Ort Quelle:Bognor Regis : Wiley, 1928
Jahr Quelle:2022
Band/Heft Quelle:95(2022), 1139, Artikel-ID 20220372, Seite 1-6
ISSN Quelle:1748-880X
Abstract:Objectives: To define reference values for shear wave elastography (SWE) in unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination. Methods: In total, 177 clinically and sonographically unsuspicious axillary lymph nodes were prospectively evaluated with SWE using Virtual Touch Tissue Imaging Quantification (VTIQ) in 175 women. Mean values of tissue stiffness for axillary fatty tissue, lymph node cortex, and lymph node hilus were measured. Additionally, test-retest reliability of SWE in the assessment of axillary lymph node stiffness was evaluated by repeating each measurement three times. Results: In 177 axillary lymph nodes, the mean stiffness of lymph node cortex, hilus, and surrounding fatty tissue as quantified by SWE was 1.90 m/s (SD: 0.34 m/s), 2.02 m/s (SD: 0.37 m/s), and 1.75 m/s (SD: 0.38 m/s), respectively. The mean stiffness of cortex and hilus was significantly higher compared to fatty tissue (p < 0.0001). SWE demonstrated good test-retest reliability in the assessment of stiffness of the lymph node hilus, cortex, and the surrounding fatty tissue with an intraclass correlation of 0.79 (95% CI: 0.75; 0.83), 0.75 (95% CI: 0.70; 0.79), and 0.78 (95% CI: 0.74; 0.82), respectively, (p < 0.0001). Conclusions: Reference values for SWE in unsuspicious axillary lymph nodes are determined. These results may help to better identify axillary lymph node metastasis for breast cancer patients when combined with other lymph node features. SWE is a reliable method for the objective quantification of tissue stiffness of axillary lymph nodes. Advances in knowledge: This study presents physiological reference values for tissue stiffness by examining the axillary lymph nodes with SWE in 175 women with sonomorphologically unsuspicious lymph nodes.
DOI:doi:10.1259/bjr.20220372
URL:kostenfrei: Volltext: https://doi.org/10.1259/bjr.20220372
 kostenfrei: Volltext: https://www.birpublications.org/doi/10.1259/bjr.20220372
 DOI: https://doi.org/10.1259/bjr.20220372
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1837132631
Verknüpfungen:→ Zeitschrift
 
 
Lokale URL UB: Zum Volltext

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69043425   QR-Code
zum Seitenanfang