Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Jakobs, Martin [VerfasserIn]   i
 Hajiabadi, Mohammad Mehdi [VerfasserIn]   i
 Aguirre-Padilla, David Hernán [VerfasserIn]   i
 Giaccobe, Peter [VerfasserIn]   i
 Unterberg, Andreas [VerfasserIn]   i
 Lozano, Andres M. [VerfasserIn]   i
Titel:Recharge PSYCH
Titelzusatz:a study on rechargeable implantable pulse generators in deep brain stimulation for psychiatric disorders
Verf.angabe:Martin Jakobs, Mohammad Mehdi Hajiabadi, David Hernán Aguirre-Padilla, Peter Giaccobe, Andreas W. Unterberg, Andres M. Lozano
E-Jahr:2023
Jahr:9 February 2023
Umfang:9 S.
Fussnoten:Online verfügbar 9. November 2022, Artikelversion 9. Februar 2023 ; Gesehen am 05.07.2023
Titel Quelle:Enthalten in: World neurosurgery
Ort Quelle:Amsterdam : Elsevier, 2010
Jahr Quelle:2023
Band/Heft Quelle:170(2023) vom: Feb., Seite e331-e339
ISSN Quelle:1878-8769
Abstract:Background - Rechargeable implantable pulse generators (r-IPGs) for deep brain stimulation (DBS) promise longer battery life and fewer replacement surgeries versus non-rechargeable systems. Long-term data on the effects of recharging in patients who received DBS for psychiatric indications is limited. The Recharge PSYCH trial is the first study that included DBS patients with psychiatric disorders treated with different r-IPG models. - Methods - Standardized questionnaires were sent to all psychiatric DBS patients with an r-IPG implanted at the time of the study. The primary endpoint was convenience of recharging. Secondary endpoints were rate of user confidence and rate of usage-related complications, as well as charge burden (defined as minutes per week needed to recharge). - Results - Data sets of n = 21 patients were eligible for data analysis. At the time of the survey patients were implanted with the r-IPG for a mean 31.8 ± 22.4 months. Prior to being implanted with an r-IPG, patients had undergone a median of 3 IPG replacements. The overall convenience of the charging process was rated as "easy" with a median of 8.0 out of 10.0 points. 33.3% of patients experienced situations in which the device could not be successfully recharged. In 38.1% of patients, therapy with the r-IPG was interrupted unintentionally. The average charge burden was 286 ± 22.4 minutes per week. - Conclusions - Patients with psychiatric disorders rated the recharging process as “easy”, but with a significantly higher charge burden and usage-related complication rates compared to published data on movement disorder DBS patients.
DOI:doi:10.1016/j.wneu.2022.11.017
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.wneu.2022.11.017
 Volltext: https://www.sciencedirect.com/science/article/pii/S1878875022015595
 DOI: https://doi.org/10.1016/j.wneu.2022.11.017
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Deep brain stimulation
 Implantable pulse generator
 Psychiatric disorder
 Questionnaire-based
 Rechargeable pulse generators
K10plus-PPN:1851797890
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/69093648   QR-Code
zum Seitenanfang