Verfasst von:Togawa, Riku [VerfasserIn]   i
 Pfob, André [VerfasserIn]   i
 Büsch, Christopher [VerfasserIn]   i
 Fastner, Sarah [VerfasserIn]   i
 Gomez, Christina [VerfasserIn]   i
 Goncalo, Manuela [VerfasserIn]   i
 Hennigs, André [VerfasserIn]   i
 Killinger, Kristina [VerfasserIn]   i
 Nees, Juliane [VerfasserIn]   i
 Riedel, Fabian [VerfasserIn]   i
 Schäfgen, Benedikt [VerfasserIn]   i
 Stieber, Anne [VerfasserIn]   i
 Tozaki, Mitsuhiro [VerfasserIn]   i
 Heil, Jörg [VerfasserIn]   i
 Barr, Richard [VerfasserIn]   i
 Golatta, Michael [VerfasserIn]   i
Titel:Intra- and interobserver reliability of shear wave elastography in breast cancer diagnosis
Verf.angabe:Riku Togawa, MD, André Pfob, MD, Christopher Büsch, MSc, Sarah Fastner, MD, Christina Gomez, MD, Manuela Goncalo, MD, André Hennigs, MD, Kristina Killinger, MD, Juliane Nees, MD, Fabian Riedel, MD, Benedikt Schäfgen, MD, Anne Stieber, MD, Mitsuhiro Tozaki, MD, Jörg Heil, MD, Richard Barr, MD, Michael Golatta, MD
E-Jahr:2023
Jahr:29 September 2023
Umfang:6 S.
Fussnoten:Online veröffentlicht: 29. September 2023 ; Gesehen am 28.11.2023
Titel Quelle:Enthalten in: Journal of ultrasound in medicine
Ort Quelle:Hoboken, NJ : Wiley, 1982
Jahr Quelle:2023
Band/Heft Quelle:(2023) online ahead of print
ISSN Quelle:1550-9613
Abstract:Objectives Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4. Methods We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability. Results ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions. Conclusion Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.
DOI:doi:10.1002/jum.16344
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1002/jum.16344
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1002/jum.16344
 DOI: https://doi.org/10.1002/jum.16344
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:B-mode ultrasound
 breast cancer
 reliability
 shear wave elastography
K10plus-PPN:1871477999
Verknüpfungen:→ Zeitschrift