Skip navigation
University library of Heidelberg
Availability: reference only

Verfügbarkeit
Location: ---
Copies: ---
heiBIB
 Online resource
Verfasst von:Friedrich, Maximilian [VerfasserIn]   i
 Munro, Donald J. [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
 Khoramnia, Ramin [VerfasserIn]   i
Titel:Characterisation of intraocular lens injectors
Paralleltitel:Charakterisierung von Intraokularlinsen-Injektoren
Verf.angabe:Maximilian Friedrich, Donald J. Munro, Gerd U. Auffarth, Ramin Khoramnia
E-Jahr:2024
Jahr:15. August 2024
Umfang:12 S.
Fussnoten:Gesehen am 18.09.2024
Titel Quelle:Enthalten in: Klinische Monatsblätter für Augenheilkunde
Ort Quelle:Stuttgart : Thieme, 1980
Jahr Quelle:2024
Band/Heft Quelle:241(2024), 8, Seite 905-916
ISSN Quelle:1439-3999
Abstract:In modern ophthalmic surgery, an intraocular lens (IOL) is commonly implanted into the patientʼs eye with an IOL injector. Many injectors are available, showing various technological differences, from the early manually loaded injector systems to the modern preloaded injectors. This review aims to give a concise overview of the defining characteristics of injector models and draws attention to complications that may occur during IOL implantation. One can differentiate injectors according to their preoperative preparation (manually loaded or preloaded), their implantation mechanism (push-type or screw-type or combined or automated), the size of the nozzle tip, the presence of an insertion depth control feature, and the injectorʼs reusability. Potential complications are IOL misconfigurations such as a haptic-optic adhesion, adherence of the IOL to the injector plunger, an overriding plunger, uncontrolled IOL rotation, a trapped trailing haptic, or damage to the IOL. Additionally, during IOL implantation, the nozzle can become damaged with scratches, extensions, cracks, or bursts to the tip. While these complications rarely produce long-term consequences, manufacturers should try to prevent them by further improving their devices. Similarly, surgeons should evaluate new injectors carefully to ensure the highest possible surgical safety.
DOI:doi:10.1055/a-2349-2158
URL:Bibliographic entry. University members only receive access to full-texts for open access or licensed publications.

Volltext: https://doi.org/10.1055/a-2349-2158
 Volltext: http://www.thieme-connect.de/DOI/DOI?10.1055/a-2349-2158
 DOI: https://doi.org/10.1055/a-2349-2158
Datenträger:Online-Ressource
Sprache:eng
K10plus-PPN:1902918053
Verknüpfungen:→ Journal

Permanent link to this item:  https://katalog.ub.uni-heidelberg.de/titel/69254438   QR-Code
zum Seitenanfang