Navigation überspringen
Universitätsbibliothek Heidelberg
Status: Bibliographieeintrag

Verfügbarkeit
Standort: ---
Exemplare: ---
heiBIB
 Online-Ressource
Verfasst von:Hasslacher, Christoph [VerfasserIn]   i
 Auffarth, Gerd U. [VerfasserIn]   i
 Rabsilber, Tanja Marina [VerfasserIn]   i
 Kulozik, Felix [VerfasserIn]   i
Titel:Safety and accuracy of a new long-term subconjunctival glucose sensor
Verf.angabe:Christoph Hasslacher, Gerd Auffarth, Isabell Platten, Tanja Rabsilber, Beate Smith, Felix Kulozik, Monika Knuth, Katharina Nikolaus and Achim Müller
E-Jahr:2012
Jahr:17 February 2012
Umfang:6 S.
Fussnoten:Accepted manuscript online: 17 February 2012 ; Gesehen am 11.09.2018
Titel Quelle:Enthalten in: Journal of diabetes
Ort Quelle:Oxford [u.a.] : Wiley-Blackwell, 2009
Jahr Quelle:2012
Band/Heft Quelle:4(2012), 3, Seite 291-296
ISSN Quelle:1753-0407
Abstract:Background: A new biosensor has been developed by EyeSense (Großostheim, Germany) that is placed into the conjunctiva of one eye to measure the glucose concentration of the surrounding tissue in a non-invasive manner. In the present study we investigated the correlation between glucose concentrations measured by the EyeSense implant and those determined by finger prick testing, as well as the tolerability and safety of the implant over a 16-week period. Methods: The study was performed in 28 diabetic patients. The biosensor was inserted under local anesthesia and sterile conditions. Correlations between capillary glucose measured by laboratory methods and interstitial glucose determined by the biosensor were investigated by inducing increases and decreases in glucose values between 60 and 300 mg/dL. Results: Most patients experienced a mild subconjunctival hemorrhage postoperatively. Except for the minor sensation of the presence of foreign body, the implants were well tolerated. Three patients lost the ocular mini insert spontaneously, whereas there was a function failure of the insert in four patients. Error grid analysis showed that the percentage of data pairs in the acceptable ranges (zone A and B) was very high (>96%). However, there was a shift from zone A to zone B during observation. This was due primarily to an increase in the lag time between capillary and interstitial measured glucose. Conclusion: The present study demonstrates good tolerability and measurement performance of the biosensor. The reasons for an increase in the lag time are still unknown; local reactions may be involved.
DOI:doi:10.1111/j.1753-0407.2012.00192.x
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: http://dx.doi.org/10.1111/j.1753-0407.2012.00192.x
 Volltext: https://onlinelibrary.wiley.com/doi/abs/10.1111/j.1753-0407.2012.00192.x
 DOI: https://doi.org/10.1111/j.1753-0407.2012.00192.x
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:diabetes mellitus
 eye
 glucose measurement system
 glucose sensor
K10plus-PPN:1580874363
Verknüpfungen:→ Zeitschrift

Permanenter Link auf diesen Titel (bookmarkfähig):  https://katalog.ub.uni-heidelberg.de/titel/68303893   QR-Code
zum Seitenanfang