Titel:Taper corrosion in total hip arthroplasty
Titelzusatz:how to assess and which design features are crucial?
Verf.angabe:Ulrike Mueller, Therese Bormann, Stefan Schroeder, Tobias Renkawitz, J. Philippe Kretzer
E-Jahr:2022
Jahr:2 June 2022
Umfang:12 S.
Fussnoten:Gesehen am 26.07.2022
Titel Quelle:Enthalten in: Journal of the mechanical behavior of biomedical materials
Ort Quelle:Amsterdam [u.a.] : Elsevier, 2008
Jahr Quelle:2022
Band/Heft Quelle:133(2022) vom: Sept., Artikel-ID 105307, Seite 1-12
ISSN Quelle:1878-0180
Abstract:Background - In total hip replacement, wear and corrosion arising from modular taper connections have increasingly become a serious clinical concern. Previous studies led to confounding results regarding the role of specific taper design features, likely due to the application of different analytical approaches. Accordingly, this study has two major objectives: first, to evaluate different analytical approaches to evaluate the fretting-corrosion behavior; and secondly to determine the effect of four specific design variables: the taper engagement situation, the stem taper length and surface topography in terms of roughness and contact ratio. - Methods - An in vitro fretting-corrosion test setup was used including an aggressive solution. Cyclic loading was applied, varying from 300 N to 2500 N at a frequency of 3 Hz. Taper dummies covering different implant designs were tested in seven different test groups. Different quantitative and qualitative analytical test methods such as electrochemical characterization, ion analysis, gravimetry and corrosion scoring were applied in order to quantify the material degradation. - Results - A stepwise linear regression analysis showed that the taper engagement situation is the predominant factor that predicts the metal ion release from the taper connection, followed by the contact ratio of the taper surface and subsequently the taper length. A distal taper engagement situation, as well as a high contact ratio and a short taper length are the relevant parameters that decrease the metal ion release. Hereby, metal ion analysis turned out to be the most precise and reliable method for determining corrosive driven material loss, followed by gravimetry. - Conclusion - It was found that the taper engagement length is the major design parameter that influences the total ion release. It further turned out, that the selection of an appropriate analytical approach is essential for the evaluation of the corrosion behavior of taper connections in an experimental setting.
DOI:doi:10.1016/j.jmbbm.2022.105307
URL:Bitte beachten Sie: Dies ist ein Bibliographieeintrag. Ein Volltextzugriff für Mitglieder der Universität besteht hier nur, falls für die entsprechende Zeitschrift/den entsprechenden Sammelband ein Abonnement besteht oder es sich um einen OpenAccess-Titel handelt.

Volltext: https://doi.org/10.1016/j.jmbbm.2022.105307
 Volltext: https://www.sciencedirect.com/science/article/pii/S175161612200220X
 DOI: https://doi.org/10.1016/j.jmbbm.2022.105307
Datenträger:Online-Ressource
Sprache:eng
Sach-SW:Fretting-corrosion
 Head-stem taper junction
 In vitro testing
 Surface topography
 Taper angle difference
 Taper length
 Total hip arthroplasty (THA)